The independent control structure of the cold and hot box is adopted, with a temperature conversion time of less than 15 seconds and a temperature recovery time of less than 5 minutes. It is equipped with multiple safety interlock protection and standard lead hole design to ensure efficient and safe testing.
With the independent control structure of the cold and hot box, the temperature conversion takes only 15 seconds and the recovery time does not exceed 5 minutes. The temperature fluctuation in the sample area is controlled within +/- 0.5 ° C, the load-bearing capacity is up to 40kg, and it is equipped with safety interlock protection and 7-inch Touchscreen controller.
Adopt independent control structure of hot and cold box, temperature conversion time ≤ 15 seconds, temperature recovery ≤ 5 minutes, equipped with safety interlock protection and 7-inch Touchscreen controller, support long-term adjustable test.
Adopt triple-channel thermal insulation structure to realize cold and hot air circuit switching, temperature recovery time within 5 minutes, Impact time up to 9999 minutes, with 96 test specifications independently set and automatic defrosting function.
Adopt -80 ° C cold trap temperature and 4kg/batch water, equipped with pre-freezing function without additional equipment, color Touchscreen display paraMeters, support for a variety of container freeze-drying and automatic maintenance reminders.
The use of professional gas diversion technology has good water capture effect, and the cold trap temperature reaches -80 ° C to capture 4kg of water. Support sample pre-freezing and lyophilization of various containers, with data export and remote control functions, built-in maintenance reminders and vacuum alarm systems.
Adopting independent control design of hot and cold box, the temperature conversion time does not exceed 15 seconds, and the recovery time is within 5 minutes. Equipped with safety interlock function and standard lead hole tube, it enhances test efficiency and operation safety.
Danfoss Compressor to achieve -60 ℃ low temperature, water capture up to 4kg/batch. With cold trap pre-freezing function without additional equipment, color Touchscreen display operating paraMeters, support data export and remote control.
Temperature conversion time ≤ 15 seconds, temperature recovery ≤ 5 minutes, cold and hot box independent control does not interfere with each other, with sample area temperature fluctuation ≤ +/- 0.5 ℃ High Accuracy thermostatic performance, improve test reliability.
Impact height up to 120 cm, weight weight mass 1000g, no secondary rebound after impact, to ensure accurate and reliable test results, suitable for film impact performance evaluation.
Adopting independently controlled hot and cold box structure, the temperature conversion time does not exceed 15 seconds, the recovery time is within 5 minutes, and it is equipped with a 7-inch Touchscreen controller with an accuracy of +/- 0.1 ° C, supporting a sample load of 20kg, suitable for a variety of testing needs.
Adopting the independent control structure of the cold and hot box, the temperature conversion time is ≤ 15 seconds, and the temperature recovery is ≤ 5 minutes. Equipped with safety interlock protection, the temperature fluctuation in the sample area is ≤ +/- 0.5 ° C, supporting long-term stable operation.
Impact height 0-50cm adjustable, equipped with 1000g drop weight and Φ 8mm punch, Impact depth 2mm, can accurately determine the material resistance to Impact performance.
Impact height up to 120 cm, using 1000g standard hammer body, no secondary rebound phenomenon after impact, to ensure accurate and reliable test results.
Impact height 0-100cm adjustable, equipped with 1000g drop weight and Φ 8mm punch, Impact depth 2mm, can accurately determine the material anti-Impact performance.