Hot and Cold Box

The thermal chamber regulates its internal temperature through cooling and heating systems to simulate different environmental conditions, and is used to test the performance of materials under temperature variations. It is commonly employed in weathering tests for products such as coatings and plastics.
Selection
When selecting a cold and hot chamber, consider the temperature range, control accuracy, chamber size, and material compatibility to ensure the equipment meets testing standards. Pay attention to energy consumption and maintenance requirements, and match them according to the specific application scenarios.

Terms

Standards

Instruments

With the independent control structure of the cold and hot box, the temperature conversion takes only 15 seconds and the recovery time does not exceed 5 minutes. The temperature fluctuation in the sample area is controlled within +/- 0.5 ° C, the load-bearing capacity is up to 40kg, and it is equipped with safety interlock protection and 7-inch Touchscreen controller.

$ 38608.00

The independent control structure of the cold and hot box is adopted, with a temperature conversion time of less than 15 seconds and a temperature recovery time of less than 5 minutes. It is equipped with multiple safety interlock protection and standard lead hole design to ensure efficient and safe testing.

$ 34606.00

Adopt independent control structure of hot and cold box, temperature conversion time ≤ 15 seconds, temperature recovery ≤ 5 minutes, equipped with safety interlock protection and 7-inch Touchscreen controller, support long-term adjustable test.

$ 42981.00

Adopting independent control design of hot and cold box, the temperature conversion time does not exceed 15 seconds, and the recovery time is within 5 minutes. Equipped with safety interlock function and standard lead hole tube, it enhances test efficiency and operation safety.

$ 29120.00

The independent control of the hot and cold box realizes three uses in one box, the temperature conversion time is ≤ 15 seconds and the recovery time is ≤ 5 minutes, the temperature fluctuation in the sample area is ≤ +/- 0.5 ° C, and it is equipped with multiple safety interlock protection and 7-inch Touchscreen control.

$ 38414.00

Temperature conversion time ≤ 15 seconds, temperature recovery ≤ 5 minutes, cold and hot box independent control does not interfere with each other, with sample area temperature fluctuation ≤ +/- 0.5 ℃ High Accuracy thermostatic performance, improve test reliability.

$ 25328.00

Adopting the independent control structure of the cold and hot box, the temperature conversion time is ≤ 15 seconds, and the temperature recovery is ≤ 5 minutes. Equipped with safety interlock protection, the temperature fluctuation in the sample area is ≤ +/- 0.5 ° C, supporting long-term stable operation.

$ 25328.00

Adopting independently controlled hot and cold box structure, the temperature conversion time does not exceed 15 seconds, the recovery time is within 5 minutes, and it is equipped with a 7-inch Touchscreen controller with an accuracy of +/- 0.1 ° C, supporting a sample load of 20kg, suitable for a variety of testing needs.

$ 22471.00

The temperature conversion time only takes 15 seconds, the recovery time does not exceed 5 minutes, equipped with a 7-inch Touchscreen controller, with an accuracy of +/- 0.1 ° C, and an independent cold and hot box design to improve test efficiency and safety.

$ 34429.00

Adopting an independent control structure of a cold and hot box, the temperature conversion time is less than or equal to 15 seconds, the temperature recovery time is less than or equal to 5 minutes, and it has the ability to accurately control the temperature in the sample area with a temperature fluctuation of less than or equal to +/- 0.5 ° C, supporting an adjustable test time of 9999 hours.

$ 32734.00

Adopt three-box heat storage and cold storage structure, temperature conversion time ≤ 10 seconds, Temperature range -65 ℃~ + 150 ℃, with independent temperature control functions in high temperature zone, low temperature zone and test zone, and can perform 2-box or 3-box Impact mode.

$ 20261.00

Adopt stainless steel shaft impeller forced convection cycle, Temperature Uniformity +/- 1 ℃, adjustable ventilation rate 8-20 times/hour, with independent ventilation system and sample holder swirl/spin function.

$ 4317.00

Temperature range RT + 10~ 300 ℃, Temperature Uniformity +/- 1 ℃, with automatic ventilation system can adjust the ventilation volume 8~ 20 times/hour, sample holder can swirl/spin to ensure test uniformity.

$ 3946.00

Temperature range -25 ℃, temperature control accuracy +/- 1 ℃, can simulate the natural low temperature environment for bending test, observe material changes, determine the degree of cold resistance.

$ 6770.00

Temperature control accuracy +/- 1 ℃, rapid heating and over-temperature automatic interrupt function, adjustable fan Rotation speed and timing control, easy to clean the box.

$ 838.00

Articles

Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.
Technical Differences Between Two-Chamber and Three-Chamber Thermal Shock Test Chambers
The thermal shock test chamber is used to test a product's resistance to sudden temperature changes, primarily through two methods: the two-chamber method and the three-chamber method. What are the differences between them? This article will tell you!
The difference between thermal shock test chambers and constant temperature and humidity chambers
This article compares the differences between thermal shock test chambers and constant temperature and humidity chambers in terms of working principles, key performance, and applications.